Skip to main content
  • Published:

Internal current generation in respiration chambers

Abstract

A technical device generating a constant and directed current within a sealed respiration chamber is described. It does not involve any external pumps or tubing. This system is easy to handle, and improved the maintenance of rheotactic pelagic species like the Northern krill (Meganyctiphanes norvegica, Crustacea) or small fishes (Gasterosteus aculeatus) under experimental conditions.

Literature Cited

  • Belman, B. W. & Gordon, M. S., 1979. Comparative studies on the metabolism of shallow-water and deep-sea marine fishes. V. Effect of temperature and hydrostatic pressure on oxygen consumption in the mesopelagic zoarcidMelanostigma pammelas.—Mar. Biol.50, 275–281.

    Article  Google Scholar 

  • Bulnheim, H.-P., 1974. Respiratory metabolism ofIdotea balthica (Crustacea, Isopoda) in relation to environmental variables, acclimation processes and moulting.—Helgoländer wiss. Meeresunters.26, 464–480.

    Article  Google Scholar 

  • Chapelle, G. & Peck, L.S., 1995. The influence of acclimation and substratum on the metabolism of the Antarctic amphipodsWaldeckia obesa (Chevreux 1905) andBovallia gigantea (Pfeffer 1888).—Polar Biol.15, 225–232.

    Article  Google Scholar 

  • Eriksen, C. H. & Feldmeth, C. R., 1967. A water-current respirometer.—Hydrobiologia29, 495–504.

    Article  Google Scholar 

  • Gordon, M. S. & Thomas, T. J., 1974. Comparative studies on the metabolism of shallow-water and deep-sea marine fishes. III. Apparatus for studies of tissue preparations under high hydrostatic pressures.—Mar. Biol.28, 73–77.

    Article  Google Scholar 

  • Kils, U., 1981. The swimming behavior, swimming performance and energy balance of Antarctic krill,Euphausia superba.—BIOMASS Sci. Ser.3, 1–122.

    Google Scholar 

  • Quetin, L. B., 1983. An automated, intermittent flow respirometer for monitoring oxygen consumption and long-term activity of pelagic crustaceans. In: Polarographic oxygen sensors. Ed. by E. Gnaiger & H. Forster. Springer, Berlin, 176–183.

    Google Scholar 

  • Quetin, L. B. & Mickel, T. J., 1983. Sealed respirometers for small invertebrates. In: Polarographic oxygen sensors. Ed. by E. Gnaiger & H. Forster, Springer, Berlin, 184–189.

    Google Scholar 

  • Sutcliffe, D. W., Carrick, T. R. & Moore, W. H., 1975. An automated respirometer for determining oxygen uptake in crayfish (Austropotamobius pallipes [Lereboullet]) over periods of 3–4 days.—J. exp. Biol.63, 673–688.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Saborowski, R., Buchholz, F. Internal current generation in respiration chambers. Helgoländer Meeresunters. 52, 103–109 (1998). https://doi.org/10.1007/BF02908740

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02908740

Key words